Re: A89: autoint 5 default settings (was: New e-Mail)


[Prev][Next][Index][Thread]

Re: A89: autoint 5 default settings (was: New e-Mail)




On Mon, Jan 08, 2001, Deja User wrote:
> 
> BTW, can ANYONE tell me about how to program the default value for the
> auto int 5 timer? 

The default interrupt rate values are $B2 (=79 ticks/interrupt) for HW1 and
$CC (=53 ticks/interrupt) for HW2.  Write the correct one to $600017.
Remember also to write $1B to $600015 if necessary.


-- 
Johan Eilert



References: